This
OEM nitrogen laser incorporates technology developed in a series of
contracts to supply a space hardened laser for the International
Space Station.
|
Performance
The 337-Si OEM nitrogen laser emits pulses of 4 nsec in duration
at 337 nm in the UV with a pulse energy of 300 µJ. Peak power is
75 kW and the average power is 3 mW at 10 Hz. The pulse repetition
rate can be varied from less than one pulse per second up to 10
Hz. Low EMI enables the 337-Si laser to operate side-by-side with
computers and sensitive electronics. |
Beam
Quality
The output of
the 337-Si OEM laser is near-diffraction limited producing a collimated
beam. The excellent homogeneity of the beam is shown in the beam profile.
This beam can be focused to better than a 3 µm spot producing very high
peak power and an energy density of 4.5 kJ/cm2.
Straight-Forward
Operation
The
337-Si OEM laser is air-cooled and incorporates our patented, sealed
plasma cartridge. No hookups for flowing gas or coolant are required.
No alignment is necessary as the laser resonator optics are factory
aligned and secured to the plasma cartridge. The laser needs no
warm-up. Simply connect 24 volts and a trigger through the D-sub
connector. The 337-Si is ready to go at system startup. |
|
Modular
Design
The
laser plasma cartridge module is polymer encapsulated and includes the
energy storage capacitors, the spark gap switching element, the plasma
tube, the electrodes, the preionizers, and the resonator mirrors. In
other words, this field replaceable unit incorporates all the laser
components that are subject to deterioration with usage. Replace the
cartridge; get the performance of a new laser at a fraction of the cost!
Long
Life
The
plasma cartridge is warranted to maintain at least 70% of its energy
for twenty million pulses or two years, whichever occurs first.
Options
Our
new fiber optic coupler and modular holders for filters, attenuators,
energy meters, and other optical components give the design engineer
more flexibility.
Specifications* |
Part
Number |
337203 |
Wavelength |
337.1
nm |
Spectral
Bandwidth |
0.1
nm |
Repetition
Rate |
Up
to10 Hz, user supplied trigger |
Pulse
Width, FWHM |
4
nsec |
Pulse
Energy |
300 µJ |
Pulse
to Pulse Energy Stability |
3% std. dev. at 10 Hz |
Peak
Power |
75
kW |
Average
Power |
3 mW at 10 Hz |
Beam
Area |
35
mm2 |
Beam
Divergence, Full Angle |
0.3
mrad |
Optical
Pulse to Optosync Delay |
<50
nsec, <1 nsec std. dev. jitter |
External
Trigger Input |
TTL,
optoisolated |
Trigger
In to Optical Pulse Out |
<1
msec, <40 nsec std. dev. jitter |
Power
Requirements |
+
24 volts DC, 600 mA average at 10 Hz,
<1 A peak |
Power
Consumption |
15
W at 10 Hz |
Dimensions,
l x w x h |
7.1
x 6.8 x 3.6 in; 18.1 x 17.4 x 9.2 cm |
Weight |
9 lbs; 4.1 kg |
|
* Due to our corporate policy of continuous improvement,
specifications are subject to change without notice. The 337-Si OEM
laser does not comply with the Center for Devices and Radiological Health
(CDRH) regulations in regards to time delay, remote interlock and warning
labels. Please note that this laser can only be sold for OEM use and
equipment in which the laser is being used must, as a result, comply
with CRDH regulations.
|