business > medical coating
|
LubriLAST |
Lubricous Coating |
|
LubriLASTcoatings are |
|
Lubricious: |
|
LubriLAST coatings virtually eliminate coefficient of friction in aqueous environments. |
|
Aqueous: |
|
LubriLAST coatings, since they are based on the BioLAST platform, contain no organic solvents. Safer and cleaner manufacturing processes are used and any concerns about residual solvents in a device are eliminated |
|
Durable: |
|
LubriLAST retains it's physical integrity and lubricity even after hundreds of cycles. |
|
Biocompatible: |
|
LubriLAST passes all stringent biocompatibility tests associated with tissue and blood contacting devices. |
|
Flexible: |
|
LubriLAST withstands, without flaking or delamination, use in the tortuous paths found in physiological systems. It can be applied to balloons used in a number of medical applications. |
|
Accepted: |
|
LubriLAST is patent protected (US#6,238,799,
US#6,866,936) and is in use in a number of approved devices used in neurovascular, cardiovascular, urological, and surgical applications. |
|
|
|
|
|
|
How does LubriLAST work? |
|
|
|
LubriLAST is part of the BioLAST technology platform. The supporting polymer network characteristic to BioLAST is crosslinked and covalently bound to the substrate. This network is normally non-swellable in water. In LubriLAST, a long chain, biocompatible hydrophilic polymer is incorporated into the coating. Part of this long hydrophilic polymer becomes entangled with the supporting network while other part remains exposed and able to become hydrated. When in the presence of water or body fluids, the hydrophilic polymer adsorbs water molecules to create a watery interface at the surface of the device. The water cushion reduces wet friction, protein adsorption and cell adhesion. |
|
|
|
Friction Reduction |
|
Coefficient of friction comparisons |
Surface |
Coefficient of Friction |
|
Static Kinetic |
Uncoated PE |
5.890 1.019 |
Uncoated PET |
0.328 1.291 |
PET, Silicone coated |
0.041 0.021 |
LubriLAST coated PE |
0.009 <0.005 |
|
|
(Data developed via
modified D-1894-95 protocol. Test performed in water, samples pulled against polyethylene.) |
|
Relative friction reduction for various substrates |
|
|
|
Durability |
|
|
Biocompatibility |
|
Tissue Biocompatibility
- Cytotoxicity
- Sensitization tests in guinea pigs
- Acute intracutaneous reactivity
- Pyrogen material mediated test
- Systemic toxicity
|
Hemocompatibilty
- Direct Hemolysis
- In vivo thrombogenic resistance study
- Complement activation
- Coagulation study
|
|
Sterilization and Shelf Life |
|
Medical devices coated with LubriLAST can be sterilized by:
- ETO
- Gamma
- E-beam
- Shelf life: LubriLAST sterilized products have a shelf life of 3 years
|