ECAT®
ECAT, Expert Computer Aided Testing,
addresses a broad range of EFT, Surge and Dips and Interrupts testing
to meet Bellcore, UL, IEC and ANSI standards. Designed to meet the needs
and standards of the telecommunications, power line and electrical industries
as well as EMI test laboratories.
The ECAT is the most comprehensive test system offered
by KeyTek for analyzing product vulnerability. It has become the industry
leader in technology, functionality and reliability. The precision with
which ECAT pulsed EMI tests are performed eliminates the possibility of
overtest which may indicate unnecessary re-engineering and increased production
costs; it also eliminates the possibility of undertest which can leave
your product vulnerable to reliability problems as a result of real world
stresses.
A comprehensive, open architecture allows custom configurations
to be easily assembled. And, each year new modules are introduced to expand
the test capabilities of the system and to continually meet evolving test
standards and customer requirements.
Designed as a flexible, economically upgradable modular
system, a stand-alone system can be upgraded at any time with the simple
addition of new modules thereby eliminating costly equipment obsolescence
and redundancies.
The ECAT meets the test levels and requirements in accordance
with national and international standards, including:
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-11
ANSI/IEEE C62.41
UL 864
UL 1449
FCC Part 68
CCITT Rec. K.17, K.20, K.21
Bellcore-1089-CORE
British Telecom Standards
The ECAT has an industry standard warranty of one year
with expanded warranty programs available.
Available ECAT Test Modules and Capabilities, Build
Your Own ECAT System!
EFT
- EFT burst testing to 4.4kV
Model E421
- EFT burst testing to 8kV Model
411
- EFT burst testing to 4.4kV with built-in single-phase
AC mains coupler/decoupler in accordance with IEC 61000-4-4 Model
E412
- EFT burst testing to 8kV with built-in single-phase AC
mains coupler/decoupler in accordance with IEC 61000-4-4 Model
E422
- EFT burst testing to 4.4kV with built-in three-phase
AC mains coupler/decoupler in accordance with IEC 61000-4-4 Model
E423
- EFT burst testing to 8kV with built-in three-phase AC
mains coupler/decoupler in accordance with IEC 61000-4-4 Model
E434
SURGE
- IEC 61000-4-5, ANSI/IEEE C62.41 Cat. B and UL 1449 at
3kA Model E501B
- Telecom surge waves per IEC 61000-4-5, FCC Part 68 and
CCITT Rec. K.17, K.20 and K.21 Model
E502B
- Ring waves specified by ANSI/IEEE C62.41 Cat A and B
and various UL standards including UL 864 Model
E503
- Combination waves per UL 1449 Model
E504A
- Lightning surge waveforms required by FCC Part 68 Telecom
Model E505
- Three-terminal 2/10ms
telecom waves per Bellcore GR-1089-CORE Model
E506
- Up to five-wire (four-terminal) testing with 2/10ms
telecom waves required by Bellcore GR-1089-CORE Model
E506-4W
- 10/360ms telecom surge
wave required by Bellcore GR-1089-CORE Model
E508 & E508-12P
- Telecom True three-terminal testing using 10/1000ms
voltage and current waves as required by Bellcore GR-1089-CORE Model
E509A
- Extended range combination wave specified by ANSI/IEEE
C62.41 Cat B and IEC 61000-4-5 to 10kV and 5kA Model
E510A
- High current combination waves to 6kV and 5kA as required
by British Telecom standards Model
E511
- Voltage ramps for testing surge protection components,
such as gas arresters, as required by UL 864 Model
E513
- Two terminal voltage ramps and 10/1000ms
current waves for testing telecom equipment and protectors, including
gas discharge tubes and silicon avalanche devices, as required by some
Bellcore and component standards Model
E514
- High voltage, Category C high exposure, high-current
combination waves required by ANSI C62.41 standards for service entrance
and outside connected electronics, while meeting the requirements of
IEC 61000-4-5 for all exposure categories Models
E521 and E522
- Single phase, AC line coupler/decoupler for surge waves
per IEC 61000-4-5 for power lines Model
E551
- Couple a range of surge waves to unshielded I/O lines
and telecom lines Model E571
- High energy 10/250ms
telecom waves required by Bellcore GR-1089-CORE Model
E515
- I/O line coupler/decoupler per IEC 61000-4-5
Model CM-I/OCD
- Telecom line coupler/decoupler per IEC 61000-4-5 Model
CM-TELCD
Combination
- Single and three-phase ac line coupler/decouplers for
EFT and Surge waves per IEC 61000-4-4 and IEC 61000-4-5 Model
E455x
Dips and Interrupts
- One phase of a three-phase, five-wire ac power mains
for swell, dip and interrupt testing per IEC 61000-4-11 and other standards
Model EP3
- Swells, dips and interrupts on ac power mains in compliance
with and exceeding the requirements of IEC 61000-4-11 Model
EP61 and EP62
For additional product information, please
download the ECAT brochure.
For in-depth product specification sheets, please visit our literature
room or click the appropriate link under Test
Modules and Capabilities. Or, complete the KeyTek Contact
Us.
KeyTek
One Lowell Research Center
Lowell, Massachusetts USA 01852
Tel: 978 275 0800 Fax: 978 275 0850 Email: sales@keytek.com
|