Automate Fluid Handling
 
 map map other cont site

Automation Station and Prep Station

For printing info, click: *

 

 
with
Moving Tray

S

L

Dimensions,
W x D x H
Height is Top of Probe Travel

30.75 x 18.50 x 20.60 in;
78.1 x 47.0 x
52.3 cm

30.75 x 40.40 x 20.60 in;
78.1 x 102.6 x
52.3 cm

14.25 x 16.50 x
15.75 in;
36.2 x 41.9 x
40.0 cm

23.26 x 16.50 x
15.75 in;
59.1 x 41.9 x
40.0 cm

Universal Device Platform, W x D

21.00 x 10.00 in;
53.34 x 25.4 cm 

21.00 x 20.00 in;
53.34 x 50.8 cm 

11.75 x 10.45 in;
29.8 x 26.5 cm 

20.75 x 10.45 in;
52.7 x 26.5 cm

 Capacity
12 microplates
20 microplates
3 microplates
6 microplates

Universal Device Platform

17 x 36 locating grid on
0.6 in (1.52 cm) centers

Two 17 x 28 locating grids on
0.6 in (1.52 cm) centers

17 x 15 locating grids on
0.6 in (1.52 cm) centers

32 x 15 locating grids on
0.6 in (1.52 cm) centers

Vertical Probe Travel
Programmable in  0.1 mm increments

6.80 in; 17.3 cm

 

6.80 in; 17.3 cm

4.50 in; 11.4 cm

4.50 in; 11.4 cm

Positioning Accuracy

All axes - 0.002 in; 0.05 mm
Auto aligning

All axes - 0.002 in; 0.05 mm
Auto aligning

All axes - 0.004 in; 0.1 mm
Auto Aligning

All axes - 0.004 in; 0.1 mm
Auto Aligning

Positioning, All Axes

Programmable random
access in 0.01 mm
increments

Programmable random
access in 0.01 mm
increments

Programmable random
access in 0.01 mm
increments

Programmable
random
access in 0.01 mm
increments

Programmable Velocity, All Axes

0 - 10.00 in/sec; 0 - 25.4 cm/sec in 1% of full speed increments

End-of-travel acceleration and deceleration are standard

0 - 10.00 in/sec; 0 - 25.4 cm/sec in 1% of full speed increments

End-of-travel acceleration and deceleration are standard 

Moving Tray velocity 4.00 in / sec; 10.2 cm/sec

0 - 4.00 in/sec; 0 - 10.2 cm/sec
in 1% of full speed increments 

 End-of-travel acceleration and deceleration are standard

  0 - 4.00 in/sec; 0 - 10.2 cm/sec
in 1% of full speed increments 

End-of-travel acceleration and deceleration are standard

Control Interfaces

 

 

 

 

 

1 Universal Serial Bus Port

2 RS-232 Serial Ports

2 RS-485 Serial Ports

3 TTL Input Pins

3 TTL Output Pins

Configurable Switches

Even or No Parity

1 Universal Serial Bus Port

2 RS-232 Serial Ports

2 RS-485 Serial Ports

3 TTL Input Pins

3 TTL Output Pins

Configurable Switches

Even or No Parity

1 Universal Serial Bus Port

2 RS-232 Serial Ports

2 RS-485 Serial Ports

3 TTL Input Pins

3 TTL Output Pins

Configurable Switches

Even or No Parity

1 Universal Serial Bus Port

2 RS-232 Serial Ports

2 RS-485 Serial Ports

3 TTL Input Pins

3 TTL Output Pins

Configurable Switches

Even or No Parity

Power Requirements

85 to 240VAC Auto Selecting

50 to 60 Hz

85 to 240VAC Auto Selecting

50 to 60 Hz

85 to 240VAC Auto Selecting

50 to 60 Hz

85 to 240VAC Auto Selecting

50 to 60 Hz

Probe Management
Custom probe / tip styles and tubing management systems are available

Quick Change Probe Head for Septa Piercing

Disposable Pipette Tips

Multiple Probe Heads

Quick Change Probe Head for Septa Piercing

Disposable Pipette Tips

Multiple Probe Heads

Quick Change Probe Head for Septa Piercing

Disposable Pipette Tips

Multiple Probe Heads

Quick Change Probe Head for Septa Piercing

Disposable Pipette Tips

Multiple Probe Heads

Optional Accessories
New features and
accessories are under
continuous development.
Call for details

Model 208 Syringe Pump

Model 201 Syringe Pump

Model 200 PR Peristaltic Pump

Model 200 RS Rinse Station Pump

Probe Rinse Station

Custom Racks, Adapters, and Rinse Stations


Single, Multiple, and Disposable
Pipette Probe Styles

Universal Device Platform Adapters

Model 208 Syringe Pump

Model 201 Syringe Pump

Model 200 PR Peristaltic Pump

Model 200 RS Rinse Station Pump

Probe Rinse Station

Custom Racks, Adapters, and Rinse Stations

Single, Multiple, and Disposable Pipette Probe Styles

Universal Device Platform Adapters

 Model 208 Syringe Pump

Model 201 Syringe Pump

Model 200 PR Peristaltic Pump

Model 200 RS Rinse Station Pump

Probe Rinse Station

Custom Racks, Adapters, and Rinse Stations

Single, Multiple, and Disposable Pipette Probe Styles

Universal Device Platform Adapters

Model 208 Syringe Pump

Model 201 Syringe Pump

Model 200 PR Peristaltic Pump

Model 200 RS Rinse Station Pump

Probe Rinse Station

Custom Racks, Adapters, and Rinse Stations

Single, Multiple, and Disposable Pipette Probe Styles

Universal Device Platform Adapters

Software

Vista Software, Windows NT, 95 & 98 compatible

Vista Software, Windows NT, 95 & 98 compatible

Vista Software, Windows NT, 95 & 98 compatible

Vista Software, Windows NT, 95 & 98 compatible


* For best results, print table in landscape mode.