TecNu Electroplating Equipment Products and Services company information news links tech support conacting TecNu

electroplating equipment products contract manufacturing services
 
DC Power Supplies
Periodic Pulse  & Pulse Reverse Power Supplies
Multiple Wave Sequencing Power Supplies
Duty Cycle & Frequency Calculator
Options

 

  



"Airpax is an industry leader in electronic packages dedicated to the telecommunications industry. Upon first receiving a TecNu pulse power supply we placed it on our production line, and with no optimization, achieved a 50% improvement in cycle time with deposit characteristics remaining the same over the surface."
(Troy Krall, Air Pax-
Cambridge, MD)

 

  
 
TECNU™ periodic pulse (PP) and periodic pulse reverse (PPR) power supplies enable control of the On-Time (Forward), Off-Time (Reverse), On-Amplitude (Forward) and Reverse Amplitude (if applicable). The additional control variables over DC, provide control over the electrochemical process by affecting such properties as the diffusion layer, grain size and nucleation. Proper selection of these variables, yield deposit results which can not be attained by conventional direct current at comparable deposition rates.

WAVEFORMS: Periodic Pulse (PP) and DC
TYPICAL APPLICATIONS: Precious & semiprecious metals, flatter deposit, electroforming, PCB (non throwing power applications), laboratory use, and the electronics industry in general.

12VDC standard models (Other models available upon request)
Model Numer
Max. Avg Amps
Max. Peak Amps
Amps resolution
Volts
Volts resolution
VAC input
Phase
Digital LCD Meters
Menu Driven Control
Totalizer
Front Panel Calibration
PP10/12-1Z
10
10
.001/.01
12
0.1
120
1
S
S
Amp-Min
S
PP150-250/12-3
150
250
1
12
0.1
208
3
S
S
Amp-Min
S
PP300-500/12-3
300
500
1
12
0.1
208
3
S
S
Amp-Min
S
 S=Standard              
 

 GENERAL SPECIFICATIONS FOR PERIODIC PULSE POWER SUPPLY

Default Input Volt:
208 - 240 VAC 3ø 50/60 Hz
Regulation
Line and load
Output Voltage
6VDC, 12VDC, 24 VDC and 48 VDC
  Standard Features
Controller
Internal microprocessor for precise operation
User Control
Menu driven digital adjustments.
Meters
Voltage: back lit LCD 3 digits
Current: back lit LCD 4 digits
Amp-Hour Counter: back lit LCD 8 digits
Amp-Hour Counter
Includes Reset Control
Wave Form Library
16 Programmable memory registers
Output Connectors
Industry standard bus bars
Construction
Fully environmentally sealed for reliability
Cooling
Forced air with thermal sense
Non-volatile memory
User setting are stored and maintained with no battery or power required.
Calibration
Quick & simple front panel calibration of meters for compliance to quality and government standards
User Control
Menu driven digital adjustments


 

WAVEFORMS: Periodic Pulse (PP), Periodic Pulse Reverse(PPR), and DC
TYPICAL APPLICATIONS: Improved throwing power, PCB, semiconductor, microcircuits, electoforming, electro machining, and the electronics industry in general.

12VDC standard models (Other models available upon request)
Model Numer
Max. Avg or Fwd Amps
Peak or Rev Amps
Amps resolution
Volts
Volts resolution
VAC input
Phase
Digital LCD Meters
Menu Driven Control
Totalizer
Front Panel Calibration
PR10/12-1Z
+/- 10
+/- 10
.001/.01
12
0.1
120
1
S
S
Amp-Min
S
PR10-30/12-1Z
+/- 10
+/- 30
.01/.1
12
0.1
120
1
S
S
Amp-Min
S
PR50-100/12-3
+/- 50
+/- 100
1
12
0.1
208
3
S
S
Amp-Min
S
PR100-300/12-3
+/- 100
+/- 300
1
12
0.1
208
3
S
S
Amp-Min
S
PR250-750/6-3
250
-750
2
4/-12
0.1
208
3
S
S
Amp-Hr
S
PR250-750/6-3D*
2x250
2x -750
2
4/-12
0.1
208
3
S
S
Amp-Hr
S

* Dual output units are synchronized enabling independent control of each output

   S=Standard              

 GENERAL SPECIFICATIONS FOR PERIODIC PULSE REVERSE POWER SUPPLY

Default Input Volt:
208 - 240 VAC 3ø 50/60 Hz
Regulation
Line and load
Output Voltage
12VDC
  Standard Features
Controller
Internal microprocessor for precise operation
User Control
Menu driven digital adjustments.
Meters
Voltage: back lit LCD 3 digits
Current: back lit LCD 4 digits
Amp-Hour Counter: back lit LCD 8 digits
Amp-Hour Counter
Includes Reset Control
Wave Form Library
16 Programmable memory registers
Output Connectors
Industry standard bus bars
Construction
Fully environmentally sealed for reliability
Cooling
Forced air with thermal sense
Non-volatile memory
User setting are stored and maintained with no battery or power required.
Calibration
Quick & simple front panel calibration of meters for compliance to quality and government standards
User Control
Menu driven digital adjustments

 

 
 

company | news | links | tech support | contact us
electroplating equipment products | contract manufacturing services

 
© 2000, TecNu, Inc. All Rights Reserved
Site Design by Staff of Web + Print Design