ELITE ISE Na/K/CI or Li
Sodium/Potassium/Chloride or Lithium Analyzer
Usage Time:
Sodium Electrode
|
- Storage Conditions
- Laboratory Conditions
- Warranty After Installation
- 9 months
- Usage Time
- 24 - 36 months
- Number Of Test Possible
- Unknown
- Sample Material Used
- Serum, Plasma, Whole Blood & Urine
- Cleaning / Maintenance
- Wash with cleaning solution and condition with control solution
|
Potassium Electrode
|
- Storage Conditions
- Laboratory Conditions
- Warranty After Installation
- 6 months
- Usage Time
- 8 months
- Number Of Test Possible
- Unknown
- Sample Material Used
- Serum, Plasma, Whole Blood & Urine
- Cleaning / Maintenance
- Wash with cleaning solution
|
Chloride Electrode
|
- Storage Conditions
- Laboratory Conditions
- Warranty After Installation
- 1 month each one
- Usage Time
- 3 months each one
- Number Of Test Possible
- Unknown
- Sample Material Used
- Serum, Plasma, Whole Blood & Urine
- Cleaning / Maintenance
- Wash with cleaning solution
|
Lithium Electrode
|
- Storage Conditions
- Laboratory Conditions
- Warranty After Installation
- 1 month each one
- Usage Time
- 3 months each one
- Number Of Test Possible
- Unknown
- Sample Material Used
- Serum, Plasma, Whole Blood & Urine
- Cleaning / Maintenance
- Wash with cleaning solution
|
Reference Electrode
|
- Storage Conditions
- Laboratory Conditions
- Warranty After Installation
- 9 months each one
- Usage Time
- 24 - 36 months
- Number Of Test Possible
- Unknown
- Sample Material Used
- Serum, Plasma, Whole Blood & Urine
- Cleaning / Maintenance
- Wash with cleaning solution
|
Reagent Pack 400 ml.
|
- Storage Conditions
- 15°C to 30°C
- Warranty After Installation
- Not Applicable
- Usage Time
- 600 - 800 tests
- Number Of Test Possible
- 600 - 800 tests
- Sample Material Used
- Serum, Plasma, Whole Blood & Urine
- Cleaning / Maintenance
- Wash with cleaning solution
|
Air Detector
|
- Storage Conditions
- Laboratory conditions
- Warranty After Installation
- 8 months
- Usage Time
- 14 months, run whole blood reducing its usage life
- Number Of Test Possible
- Unknown
- Sample Material Used
- Serum, Plasma, Whole Blood & Urine
- Cleaning / Maintenance
- Wash with cleaning solution
|
Electro Spacer
|
- Storage Conditions
- Laboratory conditions
- Warranty After Installation
- 12 months
- Usage Time
- >24 months
- Number Of Test Possible
- Unknown
- Sample Material Used
- Serum, Plasma, Whole Blood & Urine
- Cleaning / Maintenance
- Wash with cleaning solution
|
Tubing Set
|
- Storage Conditions
- Laboratory conditions
- Warranty After Installation
- 8 months
- Usage Time
- >12 months, run whole blood reducing its usage life
- Number Of Test Possible
- Unknown
- Sample Material Used
- Serum, Plasma, Whole Blood & Urine
- Cleaning / Maintenance
- Wash with cleaning solution
|
Septum
|
- Storage Conditions
- Laboratory conditions
- Warranty After Installation
- 45 days
- Usage Time
- Replace with reagent pack
- Number Of Test Possible
- 600 - 800 tests
- Sample Material Used
- Serum, Plasma, Whole Blood & Urine
- Cleaning / Maintenance
- Wash with cleaning solution
|
Shelf Life After Production Information
Ordering Information
Resources 1 | Resources 2 | Resources 3 | Resources 4 | Resources 5 | Web Design Directory