Electra Medical Corporation is a leading provider of Small centrifuges, Angular Rotor Centrifuges, Fixed Angle Rotor Centrifuge, Capillary Tube Centrifuge, basic bench top centrifuges, Stainless Steel Incubators, PID Controlled Incubators, Triple Isolation, incubators, Digital Display Incubators, Cooled Incubators, Air forced ventilation incubators, Medium lab incubators, Natural Convection Dry air sterilizers, PID Controlled Sterilizers, Stainless steel ovens, Vacuum ovens, Vacuum Drying Function autoclave, bench top autoclaves, Various capacities autoclaves, small steam sterilizers, large capacity steam sterilizer, unstirred water baths, general purpose water baths, shaking water bath, circulator/water baths
ELITE ISE Na/K/CI or Li
Sodium/Potassium/Chloride or Lithium Analyzer

Usage Time:

Sodium Electrode
Storage Conditions
Laboratory Conditions
Warranty After Installation
9 months
Usage Time
24 - 36 months
Number Of Test Possible
Unknown
Sample Material Used
Serum, Plasma, Whole Blood & Urine
Cleaning / Maintenance
Wash with cleaning solution and condition with control solution
Potassium Electrode
Storage Conditions
Laboratory Conditions
Warranty After Installation
6 months
Usage Time
8 months
Number Of Test Possible
Unknown
Sample Material Used
Serum, Plasma, Whole Blood & Urine
Cleaning / Maintenance
Wash with cleaning solution
Chloride Electrode
Storage Conditions
Laboratory Conditions
Warranty After Installation
1 month each one
Usage Time
3 months each one
Number Of Test Possible
Unknown
Sample Material Used
Serum, Plasma, Whole Blood & Urine
Cleaning / Maintenance
Wash with cleaning solution
Lithium Electrode
Storage Conditions
Laboratory Conditions
Warranty After Installation
1 month each one
Usage Time
3 months each one
Number Of Test Possible
Unknown
Sample Material Used
Serum, Plasma, Whole Blood & Urine
Cleaning / Maintenance
Wash with cleaning solution
Reference Electrode
Storage Conditions
Laboratory Conditions
Warranty After Installation
9 months each one
Usage Time
24 - 36 months
Number Of Test Possible
Unknown
Sample Material Used
Serum, Plasma, Whole Blood & Urine
Cleaning / Maintenance
Wash with cleaning solution
Reagent Pack
400 ml.
Storage Conditions
15°C to 30°C
Warranty After Installation
Not Applicable
Usage Time
600 - 800 tests
Number Of Test Possible
600 - 800 tests
Sample Material Used
Serum, Plasma, Whole Blood & Urine
Cleaning / Maintenance
Wash with cleaning solution



Air Detector
Storage Conditions
Laboratory conditions
Warranty After Installation
8 months
Usage Time
14 months, run whole blood reducing its usage life
Number Of Test Possible
Unknown
Sample Material Used
Serum, Plasma, Whole Blood & Urine
Cleaning / Maintenance
Wash with cleaning solution
Electro Spacer
Storage Conditions
Laboratory conditions
Warranty After Installation
12 months
Usage Time
>24 months
Number Of Test Possible
Unknown
Sample Material Used
Serum, Plasma, Whole Blood & Urine
Cleaning / Maintenance
Wash with cleaning solution
Tubing Set
Storage Conditions
Laboratory conditions
Warranty After Installation
8 months
Usage Time
>12 months, run whole blood reducing its usage life
Number Of Test Possible
Unknown
Sample Material Used
Serum, Plasma, Whole Blood & Urine
Cleaning / Maintenance
Wash with cleaning solution
Septum
Storage Conditions
Laboratory conditions
Warranty After Installation
45 days
Usage Time
Replace with reagent pack
Number Of Test Possible
600 - 800 tests
Sample Material Used
Serum, Plasma, Whole Blood & Urine
Cleaning / Maintenance
Wash with cleaning solution


Shelf Life After Production Information

Ordering Information







Resources 1 | Resources 2 | Resources 3 | Resources 4 | Resources 5 | Web Design Directory